XQ60 Tier 4 Final

XQ60

With a robust, rental-ready construction, the 48 KW (60 kVA) XQ60 generator is designed to be easily transported around project sites safely and efficiently.

XQ60 Tier 4 Final

With a robust, rental-ready construction, the XQ60 is designed to be easily transported around project sites safely and efficiently. A smaller footprint saves space and provides installation versatility on worksites. The XQ60 is capable of 500-hour oil change intervals, which likewise increases uptime, lowers maintenance costs and consumes fewer parts and oil making it friendlier for the environment.
Electric Power

Rating Prime

46 ekW (57.5 kVA)

Frequency

60 Hz

Voltage

120 - 480 V
  • Specifications
  • Standard / Optional Features
  • Overview
    • Long Name -XQ60
    • Name -XQ60 Tier 4 Final
    • Brand -Caterpillar
    • Status -Current
  • Generator Set
    • Rating Prime - 46 ekW (57.5 kVA)
    • Frequency - 60 Hz
    • Voltage - 120 - 480 V
  • Engine
    • Engine - Cat C3.6
    • Fuel - Diesel
  • Dimensions
    • Height - Without Trailer - 65.3 in / 1658 mm
    • Length - Without Trailer - 106.5 in / 2705 mm
    • Width - Without Trailer - 41.3 in / 1049 mm
    • Weight with Lube Oil and Coolant, Without Trailer - 1423 kg / 3137 lb
  • Fuel Consumption
    • 100% Load 60Hz - 3.3 gal/hr / 12.4 l/hr
    • 75% Load 60Hz - 2.6 gal/hr / 9.77 l/hr
    • 50% Load 60Hz - 1.9 gal/hr / 7.1 l/hr
  • Noise rating (with enclosure)
    • Sound Power @ 7 meters (23 feet) @ All Ratings - 67 dB(A)
  • Standard Equipment

    • cat c3.6l diesel engine
      • Heavy-duty.
        After treatment
    • generator
      • 1514P Frame
    • control panel
      • XQCP dgital set mounted controller
    • cat connect remote monitoring
      • Provides package monitoring and management
    • cooling system
      • Package mounted radiator with vertical air discharge.
        Filled from factory
    • charging / starting system
      • 12V heavy duty starting motor and charging alternator c/w battery isolator
    • fuel system
      • 24 hour dual wall fuel tank with 3 way directional valve for external supply
    • air filter
      • Cyclonic/paper with dust cup and service indicator
    • distribution
      • Single, robust enclosure for controls and distribution c/w 4 pole circuit breaker and safety cut off
    • structure
      • Heavy Duty steel base frame with integral fuel tank.
        Lifting frame and 4 point lift.
        base frame is wider than enclosure to protect generator set during transportation
    • enclosure
      • Sound attenuating, galvanised steel enclosure with exceptional noise reduction performance
    • exhaust
      • Integrated spark arresting silencer
    • lube oil
      • On engine primary and secondary oil filters. Filled from factory
    • general
      • Factory tested and inspected