XQ35 Tier 4 Final
XQ35
With a robust, rental-ready construction, the 28 kW (35 kVA) XQ35 generator is designed to be easily transported around project sites safely and efficiently environments.
XQ35 Tier 4 Final
XQ35 Tier 4 Final
With a robust, rental-ready construction, the XQ35 is designed to be easily transported around project sites safely and efficiently. A smaller footprint saves space and provides installation versatility on worksites, while a galvanized enclosure is resilient to potentially harsh environments.
Electric Power
- Specifications
- Standard / Optional Features
- Long Name -XQ35
- Name -XQ35 Tier 4 Final
- Brand -Cat
- Status -Current
- Rating Prime - 27 ekW (35 kVA)
- Frequency - 60 Hz
- Voltage - 120 - 600 V
- Rating Standby - 30 ekW (38 kVA)
- Engine - Cat C2.2
- Fuel - Diesel
- Height - Without Trailer - 63.7 in / 1617 mm
- Length - Without Trailer - 91.3 in / 2318 mm
- Width - Without Trailer - 41.4 in / 1050 mm
- Weight with Lube Oil and Coolant, Without Trailer - 2215 lb / 1003 kg
- 100% Load 60Hz - 2.3 gal/hr / 8.8 l/hr
- 75% Load 60Hz - 1.8 gal/hr / 6.7 l/hr
- 50% Load 60Hz - 1.2 gal/hr / 4.4 l/hr
- 100% Load 60Hz - 2.6 gal/hr / 9.8 l/hr
- 75% Load 60Hz - 2 gal/hr / 7.4 l/hr
- 50% Load 60Hz - 1.3 gal/hr / 4.9 l/hr
- Sound Power @ 7 meters (23 feet) @ All Ratings - 63 dB(A)
Standard Equipment
- cat c2.2t diesel engine
- Heavy-duty.
After treatment
- Heavy-duty.
- generator
- 1514J Frame
- control panel
- XQCP dgital set mounted controller
- cat connect remote monitoring
- Provides package monitoring and management
- cooling system
- Package mounted radiator with vertical air discharge.
Filled from factory
- Package mounted radiator with vertical air discharge.
- charging / starting system
- 12V heavy duty starting motor and charging alternator c/w battery isolator
- fuel system
- 24 hour dual wall fuel tank with 3 way directional valve for external supply
- air filter
- Cyclonic/paper with dust cup and service indicator
- distribution
- Single, robust enclosure for controls and distribution c/w 4 pole circuit breaker and safety cut off
- structure
- Heavy Duty steel base frame with integral fuel tank.
Lifting frame and 4 point lift.
base frame is wider than enclosure to protect generator set during transportation
- Heavy Duty steel base frame with integral fuel tank.
- enclosure
- Sound attenuating, galvanised steel enclosure with exceptional noise reduction performance
- exhaust
- Integrated spark arresting silencer
- lube oil
- On engine primary and secondary oil filters. Filled from factory
- general
- Factory tested and inspected