D450 GC

D450 GC (60 Hz) Generator Set

D450 GC C15 (60 Hz) | 450 kW Diesel Generator models represent a customizable and flexible solution for your standby applications.

D450 GC

The Cat® C15 D450 GC diesel generator sets have been developed to meet your needs in standby applications producing reliable power of 450 ekW at 60 Hz, meeting ISO 8528-5 transient response requirements and meeting U.S. Tier 3 emission norms.
Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.
Electric Power

Emissions/Fuel Strategy

U.S. EPA Tier 3 Certified
  • Specifications
  • Standard / Optional Features
  • Overview
    • Long Name -D450 GC (60 Hz) Generator Set
    • Name -D450 GC
    • Brand -Cat
    • Status -Current
  • Generator Set Specifications
    • Standby Rating - 450 ekW
    • Prime Power Rating - 410 ekW
    • Emissions/Fuel Strategy - U.S. EPA Tier 3 Certified
    • Voltage - 480 to 600 Volts
    • Frequency - 60 Hz
    • Speed - 1800 RPM
    • Duty Cycle - Standby
  • Engine Specifications
    • Engine Model - Cat® C15 In-line 6, 4-cycle diesel
    • Bore - 5.4 in / 137 mm
    • Stroke - 6.8 in / 171 mm
    • Displacement - 928 in³ / 15.2 l
    • Compression Ratio - 16.1:1
    • Aspiration - Turbocharged Air-to-Air Aftercooled
    • Fuel System - MEUI
    • Governor Type - ADEM™A4
  • Generator Set Dimensions
    • Length - Maximum - 189.6 in / 4815 mm
    • Width - Maximum - 64.2 in / 1630 mm
    • Height - Minimum - 80.1 in / 2034 mm
    • Height - Maximum - 101.7 in / 2584 mm
    • Dry Weight - Genset (minimum) - 8172.5 lb / 3707 kg
    • Dry Weight - Genset (maximum) - 10238.3 lb / 4644 kg
  • Standard Equipment

    Optional Equipment

    • bases, mounting & fuel tanks
      • Overfill prevention valve
      • Audio & visual fuel alarm (@90% fuel level)
      • Integral and Extended 24 hr tank
      • Fuel tank pill pipe & lockable cap
      • 5 Gallon Spill Containment
    • exhaust
      • Enclosure silencer and 25 dBA Muffler
    • circuit breaker
      • Single and Multi manual breakers
      • Auxiliary contacts
    • control system
      • 100A Load center
      • Product link remote monitoring hardware
      • Twist release, Red button emergency stop
      • 20A GFCI (Ground Fault Circuit Interrupter)
      • Audible alarm Gp
      • Ground fault relay
    • enclosures
      • E-Stop
      • AC & DC Source lights
      • Sound attenuated Level 2 enclosure (White)
    • generator
      • Anti-condensation heater
      • Oversize and premium generators
      • Permanent magnet excitation (PMG) generator
      • Space heater
    • exhaust system
      • Manifold and turbocharger guards
      • Flexible exhaust connection
    • starting system
      • Standard battery set: 1000 CCA, 90 amp/hr.
      • Oversize battery set, 1400 CCA, 200 amp/hr
      • Battery charger (UL Certified)
      • Jacket water heater
    • general
      • UL2200 Certification
      • CSA Certification
      • UL 2200 package