D300 GC

D300 GC (60 Hz) Generator Set

D300 GC C9 (60 Hz) | 300 kW Diesel Generator sets are made to fufill current and future standby applications with reliable power.

D300 GC

Producing reliable power of 300 ekW at 60 Hz, our Cat® C9 D300 GC diesel generator set are designed to ISO 8528-5 transient response requirements and engineered to U.S. EPA Tier 3 emissions standards.
Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.
Electric Power

Emissions/Fuel Strategy

U.S. EPA Tier 3 Certified
  • Specifications
  • Standard / Optional Features
  • Overview
    • Long Name -D300 GC (60 Hz) Generator Set
    • Name -D300 GC
    • Brand -Cat
    • Status -Current
  • Generator Set Specifications
    • Standby Rating - 300 ekW
    • Frequency - 60 Hz
    • Emissions/Fuel Strategy - U.S. EPA Tier 3 Certified
    • Voltage - 208 to 600 Volts
    • Speed - 1800 rpm
    • Duty Cycle - Standby
  • Engine Specifications
    • Engine Model - Cat® C9 In-line 6, 4-cycle diesel
    • Bore - 4.4 in / 112 mm
    • Stroke - 5.9 in / 149 mm
    • Displacement - 538 in³ / 8.8 l
    • Compression Ratio - 16.3:1
    • Aspiration - Turbocharged Air-to-Air Aftercooled
    • Fuel System - HEUI
    • Governor Type - Adem™A4
  • Generator Set Dimensions
    • Length - Maximum - 155.5 in / 3950 mm
    • Width - Minimum - 56.3 in / 1430 mm
    • Width - Maximum - 56.7 in / 1440 mm
    • Height - Minimum - 67.2 in / 1706 mm
    • Height - Maximum - 86.7 in / 2202 mm
    • Dry Weight - Genset (minimum) - 5518.2 lb / 2503 kg
    • Dry Weight - Genset (maximum) - 6929.1 lb / 3143 kg
  • Standard Equipment

    Optional Equipment

    • bases, mounting & fuel tanks
      • Integral / Extended tank 24 hrs
      • Audio & visual fuel alarm (@90% fuel level)
      • Fuel tank pill pipe & lockable cap
    • circuit breaker
      • Auxiliary contacts
      • Single / Multi manual breakers
    • control system
      • Audible alarm Gp
      • Twist release, Red button emergency stop
      • Ground fault relay
      • 100A Load center
      • 20A GFCI (Ground Fault Circuit Interrupter)
    • enclosures
      • Sound attenuated Level 2 enclosure (White)
      • AC & DC Source lights
      • E-Stop
    • exhaust system
      • 6" Muffler - 25 dBA attenuation
      • Manifold and turbocharger guards
      • Flexible exhaust connection
    • generator
      • Space heater
      • Permanent magnet excitation (PMG) generator
    • starting system
      • Battery charger (UL Certified)
      • Jacket water heater
      • Standard battery set: 1000 CCA, 90 amp/hr.
    • general
      • CSA Certification
      • UL2200 Certification