CG132B-16
Gas Generator CG132B-16
Cat® CG132B-16 (400kW-800kW) Gas Generator models use less materials and space, allowing power plants to thrive in a value-driven age.
CG132B-16
The Cat CG132B family of gas engines are perfectly tailored to the challenges of the power plant in an age of global value chains.
The Cat CG132B family of gas engines are perfectly tailored to the challenges of the power plant in an age of global value chains.<br>
<br>
Highly efficient with low operating and installation costs and lubricant consumption, the Cat CG132B gas generator set is available with outputs from 400kW to 800kW and comes with the Total Plant and Energy Management (TPEM) system.
<br>
Highly efficient with low operating and installation costs and lubricant consumption, the Cat CG132B gas generator set is available with outputs from 400kW to 800kW and comes with the Total Plant and Energy Management (TPEM) system.
Electric Power
- Specifications
- Standard / Optional Features
- Long Name -Gas Generator CG132B-16
- Name -CG132B-16
- Brand -Caterpillar
- Status -Current
- Continuous Rating - 800 kW @1.0pf
- Fuel Type - Natural Gas, Biogas, Hydrogen Blend (up to 25%)
- Maximum Electrical Efficiency - 43.5% / 42.6%
- Maximum Standby Rating - 800 kW
- Frequency - 50 / 60 Hz
- RPM - 1500 / 1800 rpm
- Engine Model - CG132
- Displacement - 2135.8 in³ / 35 l
- Aspiration - TA
- Bore - 5.2 in / 132 mm
- Stroke - 6.3 in / 160 mm
- Length - 165 in / 4200 mm
- Width - 70 in / 1780 mm
- Height - 85 in / 2150 mm
- Dry Weight - Genset - 17691 lb / 8070 kg
Standard Equipment
- air inlet
- Turbocharger with a water-cooled bearing case for all cylinder
- One-element single-stage air cleaner with enclosure and sevice indicator
- control panels
- TPEM (Total Plant & Energy Management System)
- cooling
- Flange connections for JW inlet and outlet
- Jacket water and SCAC thermostats
- Electrical jacket water and aftercooler coolant pump
- flange connections for JW inlet and outlet
- ANSI/DN customer flange connections for JW inlet and outlet
- Cat flanges on SCAC circuit
- exhaust
- Exhaust waste gate for the CG132B-16
- Closed crankcase ventilation system
- PEARL/Low resistence exhaust system
- fuel system
- Electronic fuel metering valve
- Independently controlled cylinder monitoring and ignition system
- Pre-chamber spark plugs
- generator
- grid code generator
- Reactive droop
- closed-coupled generator result in no torque transmission to the base frame
- Busbar connections
- Anti-condensation space heater
- 3-phase sensing and KVAR/PF control
- Winding temperature detectors
- starting/charging
- 24V starting motors
- Battery disconnect switch
- general
- Crankshaft vibration damper and guard
Optional Equipment
- air inlet
- Air cleaner with precleaner
- Mounting stand
- cooling
- CHP skid
- grid code compliance
- 50Hz: Germany, Belgium, Great Britain, Italy, Poland, and Netherlands