C9 (60 Hz)

C9 Generator Set

C9 (60 HZ) 180-300 kW Diesel Generator generator sets are made to fufill current and future standby and prime applications with reliable power.

C9 (60 Hz)

The Cat® C9 diesel generator sets have been developed for standby and prime power applications, delivering reliable power from 180 to 300 ekW at 60 Hz, meeting ISO 8528-5 transient response requirements. The engines are certified to U.S. EPA Tier 3 emissions standards.
Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.
Electric Power

Emissions/Fuel Strategy

U.S. EPA Tier 3 Certified
  • Specifications
  • Standard / Optional Features
  • Overview
    • Long Name -C9 Generator Set
    • Name -C9 (60 Hz)
    • Brand -Cat
    • Status -Current
  • Generator Set Specifications
    • Standby Rating - 200/250/300 ekW
    • Prime Power Rating - 180/225/275 ekW
    • Emissions/Fuel Strategy - U.S. EPA Tier 3 Certified
    • Voltage - 220 to 480 Volts
    • Frequency - 60 Hz
    • Speed - 1800 rpm
    • Duty Cycle - Standby, Prime
  • Engine Specifications
    • Engine Model - C9 ATAAC, I-6, 4-Stroke Water-Cooled Diesel
    • Bore - 4.41 in / 112 mm
    • Stroke - 5.87 in / 149 mm
    • Displacement - 537.01 in³ / 8.8 l
    • Compression Ratio - 16.1:1
    • Aspiration - Air to Air Aftercooled
    • Fuel System - Hydraulic electronic unit injection
    • Governor Type - Adem™A4
  • Generator Set Dimensions
    • Length - Maximum - 157 in / 3988 mm
    • Width - Maximum - 47.5 in / 1207 mm
    • Height - Maximum - 73.5 in / 1867 mm
  • Standard Equipment

    • air inlet system
      • Air cleaner, light duty with disposable paper filter
    • exhaust system
      • Exhaust manifold - dry
      • Stainless steel exhaust flex, gaskets, rain cap & SAE exhaust flange for customer use - shipped loose
    • control panels
      • GCCP 1.2
    • cooling system
      • Caterpillar extended life coolant
      • Fan drive, battery charging alternator drive
      • Coolant drain line with valve
      • Radiator and cooling fan with guard
    • fuel system
      • Narrow skid base
      • Fuel cooler
      • Primary fuel filter w/integral water separator and secondary filter
      • Integral tank base
    • generators and generator attachments
      • Mandatory option circuit breaker, IEC, 3 pole mounted in power centre
      • Cold weather bundle
      • Current transformers
      • Segregated low voltage (AC/DC) wiring panel
      • Insulation Class H and temperature rise
      • Power centre, IP22
      • Automatics voltage regulator
    • governing system
      • Cat electronic governor (ADEM A4)
    • mounting system
      • Captive linear vibration isolators between base and engine-generator
      • Includes lifting provisions and termination points for coolant and lube oil drain lines
    • starting / charging system
      • Standard / Oversized batteries
    • general
      • Engine and alternator re-paint, Caterpillar yellow
    • lube system
      • Oil cooler
      • Oil drain valves
      • Fumes disposal, piped to front of radiator
      • Lubricating oil
      • Oil filter and dipstick
      • Oil drain lines with valve; piped to edge of base
    • telematics
      • Cat® Product Link™ PL444 cellular

    Optional Equipment