C175-16 (60 Hz)
C175-16 Generator Set
C175-16 (60 HZ) 2500-3100 kW Diesel Generator models are built to the highest power quality, so you can build to your power demands.
C175-16 (60 Hz)
C175-16 (60 Hz)
Producing reliable power from 2500 - 3365 ekW at 60 Hz, our C175-16 diesel generator sets are made to meet your mission critical, continuous, standby and prime applications. We've designed each to ISO 8528-5 transient response requirements and to accept 100% rated load in one step. The generator set is Low Fuel Consumption, U.S. EPA Certified for Stationary Emergency Use Only (Tier 2 Nonroad Equivalent Emission Standards) certified.
Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.
Electric Power
- Specifications
- Standard / Optional Features
- Long Name -C175-16 Generator Set
- Name -C175-16 (60 Hz)
- Brand -Cat
- Status -Current
- Standby Rating - 3365(no fan)/3250/3100(no fan)/3000 ekW
- Prime Power Rating - 3115(no fan)/3000/2825(no fan)/2725 ekW
- Emissions/Fuel Strategy - Low Fuel, Tier 2
- Voltage - 480 to 13800 Volts
- Frequency - 60 Hz
- Speed - 1800 RPM
- Duty Cycle - Standby, Mission Critical, Prime, Continuous
- Maximum Rating - 3365 ekW
- Minimum Rating - 2500 ekW
- Engine Model - C175-16 SCAC, V-16, 4-Stroke Water-Cooled Diesel
- Bore - 6.89 in / 175 mm
- Stroke - 8.66 in / 220 mm
- Displacement - 6456.31 in³ / 84.7 l
- Compression Ratio - 16.7:1
- Aspiration - Turbo Aftercooled
- Fuel System - Common Rail
- Governor Type - ADEM� A4
- Length - Minimum - 250.9 in / 6372 mm
- Length - Maximum - 330.6 in / 8398 mm
- Width - Minimum - 82.7 in / 2101 mm
- Width - Maximum - 124.3 in / 3156 mm
- Height - Minimum - 86.9 in / 2208 mm
- Height - Maximum - 134.2 in / 3410 mm
- Dry Weight - Genset (minimum) - 42750 lb / 19391 kg
- Dry Weight - Genset (maximum) - 57774 lb / 26206 kg
Standard Equipment
- air cleaner
- Single element with service indicator
- starting
- Dual electric starters
- cooling
- Standard Ambient Radiator
- crankcase ventilation system
- Non filtered crankcase ventilation
- mounting system
- Rails
- controller
- Cat ECS 100
- telematics
- Ethernet
- alternator
- Form Wound
- Permanent Magnet (PM) Excitation
- power termination
- Busbar
Optional Equipment
- air cleaner
- Dual element with service indicator
- starting
- Standard batteries
- Oversized batteries
- Battery charger - 20A
- Battery charger - 40A
- Air starter(s)
- Jacket water heater
- cooling
- No Radiator
- muffler
- Industrial grade (15 dB)
- Critical grade (25 dB)
- Hospital grade (35 dB)
- mounting system
- Rubber
- Spring vibration Isolators
- Seismic rated vibration isolators
- No Isolators
- controller
- Cat ECS 200
- EMCP 4.4
- controller attachments
- Local annunciator module
- Remote annuciator module
- Expansion I/O module
- Remote monitoring software
- telematics
- Cellular
- extended service terms
- 2 year (Prime)
- 3 year
- 5 year
- 10 year
- extended service coverage
- Silver
- Gold
- Platinum
- Platinum plus
- alternator temperature rise (over 40°c ambient)
- 80°C
- 105°C
- 125°C/130°C
- 150°C
- alternator output voltage
- 480V
- 600V
- 4160V
- 6300V
- 6600V
- 6900V
- 12470V
- 13200V
- 13800V
- alternator attachments
- Anti-condensation space heater
- Stator and bearing temperature monitoring and protection
- power termination
- Circuit breaker
- circuit breaker
- 4000A
- 5000A
- IEC
- UL
- 3-pole
- Electrically operated
- trip unit
- LSI
- LSI-G
- LSI-P
- LSIG-P
- ancilliary equipment
- Automatic transfer switch (ATS)
- Paralleling switchgear
- Paralleling controls
- certifications
- UL 2200 Listed
- IBC seismic certification
- HCAI/OSHPD OSP preapproved